  • can some body email me a standard golden nanoparticle image please

  • Dear SPM-Producers,
     
    The International NanoScience Community - www.nanopaprika.eu, scientific social network of 5550+ nanotechnology researchers, students, industrial partners and users (fifth most visited Nanotechnology Portal based on Alexa.com ranking system http://www.alexa.com/topsites/category/Science/Technology/Nanotechn...) present the first SCANNING PROBE MICROSCOPY thematic week from 20th to 25th May 2012.
     
    Blogs, news services, forum topics, thematic groups will be focusing on SPMs during this six days.
     
    We invite SPM producers and ditributors to present they products to our members and visitors, coming from more than 80 countries http://www.nanopaprika.eu/profiles/members/
    Participating fee for comapnies is 990 USD which include:
     
    - 320x90 pixel banner on main page and all subpages of www.nanopaprika.eu for 1 year
    - 5 blogpost about products of the company (based on the materials send by the company) between 20-25th May 2012
    - 1 introducing  direct mail for 5550 members (text or simple html, maximum 8000 characters)
    - 320x90 pixel banner and short info text placing on events page www.nanopaprika.eu/spm /will be live between 20-25th May 2012/
    contact: editor@nanopaprika.eu
    The International NanoScience Community
    The International NanoScience Community; Since 2007, Contact: editor@nanopaprika.eu
  • In addition to the other advice already given:

    1) Reduce the physical size of your sample as small as possible.  More mass = more thermal vibrations.

    2) Reduce the temperature of your sample (and room) as much as feasible and comfortably possible.  

    3) Dont place your AFM on a table.  It should be mounted on a heavy slab which is in turn suspended by a system of springs, much like a DJ spinning board for techno music.  If you dont have such a setup, use the heaviest table you can find.

    4) If possible, use an adhesive to attach your sample to a holding chip, but use as little adhesive as possible.  Allow at least 24 hours after affixing with the adhesive before imaging, to relieve tension.

    5) If possible, load the AFM, focus, and then allow it to sit for several hours (or an entire day) in order to come to total thermal equilibrium and reduce thermal drift and vibrations.  

  • hi sujith
    its a good information.
    i will follow these things in future..
    i want to know more about cell sample observation...
  • Dear baiju,
    First of all look at the the mode of operation. If it is contact mode then try to use cantilevers having the lowest force constant. Tapping mode works the best for all biological samples. If you have problem during scanning u can always remove cantilever and put it in ethanol for few minutes before using it again.

    second thing that is important is to find a stable environment to avoid
    vibrations which can cause noise to any scanning probe micrscope. You can avoid this by closing the door of your room and asking everybody not to enter the room during measurements. Another important point is the electrical noise. So AFM power connection should be connected only to one socket and other instrument must not be connected in to that socket.

    Regarding during experiments try to play with your servo gain. too high or low value of servo gain can always result in noise.

    Hope this helps. If u have any specific problem then let me know.. These are just generalised problem associated with scanning probe microscopes.
    best wishes..
  • hi sujith
    thanks for getting back to me..
    i am using asylum AFM
    one BIO-PD...
    not their latest saphire..
    regards
    bgnair
  • Hi Baiju,

    What mode of AFM are you using,,, could u eleborate ? Then only I will be able to comment about noise....
  • Helo Researchers
    Is there any researchers who are specialized in AFM or SPM on biological sample.I am experiencing noises when i go down to a level of 200nm size scan.
    rgrds
  • My instrument is CP II .
  • Free Online AFM Seminars

    Agilent Technologies is proud to announce a brand new series of AFM e-Seminars this spring! These one-hour live events will be led by some of the most prestigious scientists in their respective fields. The unique Agilent e-Seminar format includes an open Q&A session in which all online attendees are welcome to query the presenters.

    Choosing the Correct Cantilever for your Application
    May 13, 2009 at 3PM GMT


    Speakers: Oliver Krause, PhD NanoWorld Group
    Probe Manufacturing - Why Probes Look the Way They Do.

    In this seminar, Dr Krause will explain the reason why probes have many shapes, the different probe types that are available and what extra refinements can be done for various applications. This seminar will also give you a guide line of how to choose the correct probe for your application

    Speaker: Arvind Raman, PhD Purdue University
    Veda: a Free Online Simulation Tool for the AFM Community

    VEDA (Virtual environment for dynamic AFM) is a suite of free, cyber-enabled tools available on www.nanohub.org that simulate tapping mode AFM using magnetic/acoustic excitation (MAC/AAC) on organic and inorganic surfaces in liquids as well as ambient conditions. In this seminar, a brief introduction to the tools and their use in choosing cantilevers and operating conditions for optimal imaging will be presented